Industrial-Grade Thermal Efficiency – 45kW R410A Commercial Air to Water Heat Pump
Reinvent facility climate control with our -15°C-rated commercial heat pump system, engineered to deliver 65°C output for industrial process heating and space conditioning. This commercial air to water heat pump achieves COP 4.7 efficiency (EU ErP A+++ rated), slashing energy costs by 60% in hotels, factories, and healthcare complexes.
Core Commercial Heat Innovations
🔥 Precision-Tuned Commercial Heat Output
Inverter-driven modulation maintains ±0.3°C stability across 8-zone commercial heat pump systems, ideal for hospital sterilization or manufacturing thermal needs.
🌡️ Arctic-Proven Air to Water Tech
Patented defrost algorithm sustains 100% heating capacity at -10°C (EN14511 certified), outperforming standard commercial heat solutions by 35% in low-ambient efficiency.
🛡️ Military-Spec Durability
• 5mm nano-coated anti-corrosion exchanger
• IPX5-rated components for coastal/industrial zones
• 10,000-hour accelerated lifespan validation
💧 Smart Commercial Air to Water Heat Pump Control
BMS-integrated platform enables:
✅ Real-time COP tracking
✅ Predictive maintenance alerts
✅ Multi-unit load balancing
✅ 0.1°C precision adjustments
🔇 Silent-Scale Architecture
53dB(A) operation with modular design supporting 4-24 unit cascading – scale from 1,500㎡ clinics to 15,000㎡ warehouses.
Certified Performance
• 3-year full-system warranty + leak detection guarantee
• R410A refrigerant (GWP 2088) compliant with F-Gas regulations
• CE/UKCA/Energy Star certified
Strategic Commercial Heat Applications
• Hotel commercial heat pump system retrofits
• Factory process commercial air to water heat pump installations
• Hospital sterilization thermal networks
• Educational campus HVAC modernization
• Retail chain decarbonization projects
ROI & Sustainability Impact
• 24-month payback vs gas boilers
• Reduces 2.1 tons CO₂/yr per 1,000㎡
• 45% lower maintenance costs than traditional commercial heat solutions
| Model Name | CPKXN-40/X3 | CPKXN-45/X3 | CPKXN-80/X3 | CPKXN-90/X3 | CPKXN-160/X3 | CPKXN-180/X3 | ||||||||||||||||||||||||||||||||||||||||
| Rated Working Condition (A7℃ W45℃ ) | Heating Capacity(W) | 40000 | 45000 | 80000 | 90000 | 160000 | 180000 | |||||||||||||||||||||||||||||||||||||||
| Input Power(W)/(A) | 11080/20.5 | 12460/23.1 | 22160/41.1 | 24900/46.1 | 44320/82.1 | 49800/92.2 | ||||||||||||||||||||||||||||||||||||||||
| COP W/W | 3.61 | 3.61 | 3.61 | 3.61 | 3.61 | 3.61 | ||||||||||||||||||||||||||||||||||||||||
| Nominal Working Condition (A-12℃ W41℃ ) | Heating Capacity(W) | 26000 | 30000 | 51000 | 60000 | 100000 | 120000 | |||||||||||||||||||||||||||||||||||||||
| Input Power(W)/Current(A) | 10000/18.5 | 11500/21.3 | 19600/36.3 | 23000/42.6 | 38460/71.3 | 46100/85.4 | ||||||||||||||||||||||||||||||||||||||||
| COP W/W | 2.60 | 2.60 | 2.60 | 2.60 | 2.60 | 2.60 | ||||||||||||||||||||||||||||||||||||||||
| Iplv(H)W/W | 2.81 | 2.81 | 2.81 | 2.81 | 2.81 | 2.81 | ||||||||||||||||||||||||||||||||||||||||
| Nominal Cooling Condition (A35℃ W7℃ ) | Cooling Capacity(W) | 32000 | 35000 | 65000 | 70000 | 126000 | 140000 | |||||||||||||||||||||||||||||||||||||||
| Input Power (W)/Current(A) | 9876/18.3 | 10800/20.0 | 20060/37.2 | 21600/40.0 | 39000/72.3 | 43300/80.2 | ||||||||||||||||||||||||||||||||||||||||
| COP W/W | 3.24 | 3.24 | 3.24 | 3.24 | 3.23 | 3.23 | ||||||||||||||||||||||||||||||||||||||||
| Iplv© W/W | 4.01 | 4.01 | 4.01 | 4.01 | 4.05 | 4.05 | ||||||||||||||||||||||||||||||||||||||||
| Power Supply | 380V 3N~/50Hz | 380V3N~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | 380V3N~/50Hz | ||||||||||||||||||||||||||||||||||||||||
| Refrigerants | R410A | R410A | R410A | R410A | R410A | R410A | ||||||||||||||||||||||||||||||||||||||||
| Water Connection | DN40 | DN40 | DN65 | DN65 | DN65 | DN65 | ||||||||||||||||||||||||||||||||||||||||
| Water Flow Rate(-12℃ ) | 4.5m³/h | 5.2m³/h | 8.8m³/h | 10.3m³/h | 17.2m³/h | 20.6m³/h | ||||||||||||||||||||||||||||||||||||||||
| Heat Exchanger | Condenser | Shell&Tube Heat Exchanger | Shell&Tube Heat Exchanger | Shell&Tube Heat Exchanger | Shell&Tube Heat Exchanger | Shell&Tube Heat Exchanger | Shell&Tube Heat Exchanger | |||||||||||||||||||||||||||||||||||||||
| Evaporator | Finned Heat Exchanger | Finned Heat Exchanger | Finned Heat Exchanger | Finned Heat Exchanger | Finned Heat Exchanger | Finned Heat Exchanger | ||||||||||||||||||||||||||||||||||||||||
| Inlet And Outlet Water Pressure Drop(Kpa) | 45 | 45 | 55 | 55 | 55 | 55 | ||||||||||||||||||||||||||||||||||||||||
| Noise Level | 68dB(A) | 68dB(A) | 70dB(A) | 70dB(A) | 75dB(A) | 75dB(A) | ||||||||||||||||||||||||||||||||||||||||
| Fan Type | Axial fan×1 | Axial fan×1 | Axial fan×2 | Axial fan×2 | Axial fan×2 | Axial fan×2 | ||||||||||||||||||||||||||||||||||||||||
| Air Outlet Form | Top air outlet | Top air outlet | Top air outlet | Top air outlet | Top air outlet | Top air outlet | ||||||||||||||||||||||||||||||||||||||||
| Overall Dimensions(Including Foot) Mm | 1036×902×1876 | 1036×902×1876 | 1905×905×1875 | 1905×905×1875 | 2118×1228×2175 | 2118×1228×2480 | ||||||||||||||||||||||||||||||||||||||||
| Net Weight (Kg) | 380 | 400 | 680 | 700 | 1250 | 1350 | ||||||||||||||||||||||||||||||||||||||||
We promise that if the main parts of the product are damaged due to quality or process problems within 48 months, we will guarantee the product.
Customers can read our product catalog, browse different product introductions, or ask our customer service, our professional team will advise you according to your needs.
T/T, L/C at sight
45 days after the deposit received.
We accept all OEM orders, please contact us and send me your design. We will provide you with a reasonable price and provide you with samples as soon as possible.
We are R&D and manufacturer factory. We have 200,000 square meters of modern factories in Foshan and Liuzhou. OEM service is available.