Air Source Heat Pumps for Commercial: High-Performance Large Commercial Heat Pump Solutions
Elevate your commercial operations with our air source heat pumps for commercial use—engineered to deliver reliable, energy-efficient heating and cooling for large-scale facilities. Whether for hotels, offices, factories, or retail spaces, our air source heat pump commercial systems ensure year-round comfort while slashing operational costs.
Why Choose Our Large Commercial Heat Pumps?
✅ Unmatched Energy Efficiency
Inverter-driven technology reduces energy consumption by up to 50% compared to traditional HVAC systems, ideal for large commercial heat pumps in high-demand environments.
✅ Built for Heavy-Duty Performance
Corrosion-resistant components and industrial-grade durability ensure reliable operation in extreme temperatures and harsh conditions.
✅ 3-Year Comprehensive Warranty
Backed by robust coverage, our air source heat pumps for commercial applications guarantee long-term peace of mind.
✅ Ultra-Quiet Operation
Advanced noise reduction (<55 dB) maintains a professional ambiance, even in noise-sensitive settings like hospitals or offices.
✅ Eco-Conscious Design
R410A refrigerant minimizes environmental impact, aligning with corporate sustainability goals.
✅ Smart Scalability
Modular systems adapt effortlessly to varying commercial needs, from small offices to sprawling industrial complexes.
Ideal For:
Large commercial heat pumps in hotels, warehouses, and healthcare facilities
Upgrading HVAC efficiency in schools, shopping centers, and corporate campuses
Businesses prioritizing air source heat pump commercial reliability and ROI
Power Your Business with Sustainable Comfort
Invest in air source heat pumps for commercial success—combining cutting-edge technology, 3-year assurance, and seamless adaptability for any large-scale challenge.
| Model Name | CPKXN-40/X3 | CPKXN-45/X3 | CPKXN-80/X3 | CPKXN-90/X3 | CPKXN-160/X3 | CPKXN-180/X3 | ||||||||||||||||||||||||||||||||||||||||
| Rated Working Condition (A7℃ W45℃ ) | Heating Capacity(W) | 40000 | 45000 | 80000 | 90000 | 160000 | 180000 | |||||||||||||||||||||||||||||||||||||||
| Input Power(W)/(A) | 11080/20.5 | 12460/23.1 | 22160/41.1 | 24900/46.1 | 44320/82.1 | 49800/92.2 | ||||||||||||||||||||||||||||||||||||||||
| COP W/W | 3.61 | 3.61 | 3.61 | 3.61 | 3.61 | 3.61 | ||||||||||||||||||||||||||||||||||||||||
| Nominal Working Condition (A-12℃ W41℃ ) | Heating Capacity(W) | 26000 | 30000 | 51000 | 60000 | 100000 | 120000 | |||||||||||||||||||||||||||||||||||||||
| Input Power(W)/Current(A) | 10000/18.5 | 11500/21.3 | 19600/36.3 | 23000/42.6 | 38460/71.3 | 46100/85.4 | ||||||||||||||||||||||||||||||||||||||||
| COP W/W | 2.60 | 2.60 | 2.60 | 2.60 | 2.60 | 2.60 | ||||||||||||||||||||||||||||||||||||||||
| Iplv(H)W/W | 2.81 | 2.81 | 2.81 | 2.81 | 2.81 | 2.81 | ||||||||||||||||||||||||||||||||||||||||
| Nominal Cooling Condition (A35℃ W7℃ ) | Cooling Capacity(W) | 32000 | 35000 | 65000 | 70000 | 126000 | 140000 | |||||||||||||||||||||||||||||||||||||||
| Input Power (W)/Current(A) | 9876/18.3 | 10800/20.0 | 20060/37.2 | 21600/40.0 | 39000/72.3 | 43300/80.2 | ||||||||||||||||||||||||||||||||||||||||
| COP W/W | 3.24 | 3.24 | 3.24 | 3.24 | 3.23 | 3.23 | ||||||||||||||||||||||||||||||||||||||||
| Iplv© W/W | 4.01 | 4.01 | 4.01 | 4.01 | 4.05 | 4.05 | ||||||||||||||||||||||||||||||||||||||||
| Power Supply | 380V 3N~/50Hz | 380V3N~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | 380V3N~/50Hz | ||||||||||||||||||||||||||||||||||||||||
| Refrigerants | R410A | R410A | R410A | R410A | R410A | R410A | ||||||||||||||||||||||||||||||||||||||||
| Water Connection | DN40 | DN40 | DN65 | DN65 | DN65 | DN65 | ||||||||||||||||||||||||||||||||||||||||
| Water Flow Rate(-12℃ ) | 4.5m³/h | 5.2m³/h | 8.8m³/h | 10.3m³/h | 17.2m³/h | 20.6m³/h | ||||||||||||||||||||||||||||||||||||||||
| Heat Exchanger | Condenser | Shell&Tube Heat Exchanger | Shell&Tube Heat Exchanger | Shell&Tube Heat Exchanger | Shell&Tube Heat Exchanger | Shell&Tube Heat Exchanger | Shell&Tube Heat Exchanger | |||||||||||||||||||||||||||||||||||||||
| Evaporator | Finned Heat Exchanger | Finned Heat Exchanger | Finned Heat Exchanger | Finned Heat Exchanger | Finned Heat Exchanger | Finned Heat Exchanger | ||||||||||||||||||||||||||||||||||||||||
| Inlet And Outlet Water Pressure Drop(Kpa) | 45 | 45 | 55 | 55 | 55 | 55 | ||||||||||||||||||||||||||||||||||||||||
| Noise Level | 68dB(A) | 68dB(A) | 70dB(A) | 70dB(A) | 75dB(A) | 75dB(A) | ||||||||||||||||||||||||||||||||||||||||
| Fan Type | Axial fan×1 | Axial fan×1 | Axial fan×2 | Axial fan×2 | Axial fan×2 | Axial fan×2 | ||||||||||||||||||||||||||||||||||||||||
| Air Outlet Form | Top air outlet | Top air outlet | Top air outlet | Top air outlet | Top air outlet | Top air outlet | ||||||||||||||||||||||||||||||||||||||||
| Overall Dimensions(Including Foot) Mm | 1036×902×1876 | 1036×902×1876 | 1905×905×1875 | 1905×905×1875 | 2118×1228×2175 | 2118×1228×2480 | ||||||||||||||||||||||||||||||||||||||||
| Net Weight (Kg) | 380 | 400 | 680 | 700 | 1250 | 1350 | ||||||||||||||||||||||||||||||||||||||||
We promise that if the main parts of the product are damaged due to quality or process problems within 48 months, we will guarantee the product.
Customers can read our product catalog, browse different product introductions, or ask our customer service, our professional team will advise you according to your needs.
T/T, L/C at sight
45 days after the deposit received.
We accept all OEM orders, please contact us and send me your design. We will provide you with a reasonable price and provide you with samples as soon as possible.
We are R&D and manufacturer factory. We have 200,000 square meters of modern factories in Foshan and Liuzhou. OEM service is available.