Our Advantages:
Next-Gen Climate Control: EVI DC Inverter Heat Pump System for Ultimate Efficiency
Subtitle: Smart, Sustainable, and Trusted Worldwide
Revolutionize your home’s comfort with our EVI DC inverter heat pump system—featuring R32 Tri-generation technology. Designed for modern energy-conscious households, this advanced EVI DC heat pump integrates heating, cooling, and hot water production into one ultra-efficient unit, redefining year-round climate control.
Why Our EVI DC Inverter Heat Pump System Excels
🔥 EVI DC Inverter Technology
Maximize performance with Enhanced Vapor Injection (EVI) and DC inverter precision, delivering unmatched EVI DC inverter heat pump system efficiency even in -25°C to 48°C extremes.
🌍 Eco-Conscious R32 Refrigerant
Reduce environmental impact using low-GWP R32 refrigerant, paired with EVI DC heat pump engineering for cleaner, greener operation.
💧 Tri-Generation Versatility
Heat spaces, cool rooms, and supply hot water simultaneously—all from a single compact EVI DC inverter heat pump, slashing energy waste.
🔇 Silent & Durable Design
Engineered by leading EVI DC inverter heat pump manufacturers, our system operates below 55 dB, ensuring quiet reliability for homes and businesses.
🔋 Energy Savings Guaranteed
Cut utility bills by up to 60% compared to traditional systems, thanks to smart EVI DC inverter heat pump optimization.
Built for Longevity, Backed by Assurance
Our EVI DC inverter heat pump system features corrosion-resistant components and a 3-year comprehensive warranty, covering parts and labor. While solar integration isn’t supported, its self-sufficient design maximizes energy efficiency and reduces carbon footprints.
Ideal For:
Homes/businesses prioritizing EVI DC heat pump efficiency and versatility
Retrofits or new builds needing compact, multi-functional climate control
Eco-conscious users seeking R32 refrigerant innovation
Upgrade to Smarter Sustainability
Why choose outdated systems? Our EVI DC inverter heat pump system combines cutting-edge technology, user-friendly controls, and future-proof design. Enjoy seamless installation, minimal maintenance, and year-round comfort—all while supporting global sustainability goals.
Act Now for Advanced Climate Control!
Transform your property with a trusted EVI DC inverter heat pump engineered by industry leaders. Contact us today to explore R32 Tri-generation benefits, warranty details, and long-term savings.
Product Parameters
| Model Name: | CHP-6Ⅱ/CD3 | CHP-8Ⅱ/CD3 | CHP-10Ⅱ/CD3 | CHP-12Ⅱ/CD3 | CHP-14Ⅱ/CD3 | |||||||||||||||||||||||||||||||||||||||
| Power Supply | V/ph/Hz | 220-240V/1ph/50Hz | ||||||||||||||||||||||||||||||||||||||||||
| A7/W35 | Heating Capacity | KW | 6 | 8 | 10 | 12 | 14 | |||||||||||||||||||||||||||||||||||||
| Heating Power Input | KW | 1.32 | 1.75 | 2.26 | 2.63 | 2.88 | ||||||||||||||||||||||||||||||||||||||
| COP | W/W | 4.54 | 4.57 | 4.42 | 4.56 | 4.86 | ||||||||||||||||||||||||||||||||||||||
| A7/W55 | Heating Capacity | KW | 6 | 7.5 | 10.8 | 11.7 | 14 | |||||||||||||||||||||||||||||||||||||
| Heating Power Input | KW | 2.4 | 2.87 | 3.65 | 4.45 | 5.32 | ||||||||||||||||||||||||||||||||||||||
| COP | W/W | 2.5 | 2.61 | 2.96 | 2.63 | 2.63 | ||||||||||||||||||||||||||||||||||||||
| A35/W18 | Cooling Capacity | KW | 5.49 | 7.01 | 9.17 | 11.6 | 14.6 | |||||||||||||||||||||||||||||||||||||
| Cooling Capacity Input | KW | 1.36 | 1.58 | 1.98 | 3.32 | 3.72 | ||||||||||||||||||||||||||||||||||||||
| EER | W/W | 4.05 | 4.45 | 4.62 | 3.49 | 3.92 | ||||||||||||||||||||||||||||||||||||||
| A35/W7 | Cooling Capacity | KW | 5.7 | 7.6 | 10.3 | 10 | 14.4 | |||||||||||||||||||||||||||||||||||||
| Cooling Power Input | KW | 2.23 | 2.91 | 3.92 | 3.91 | 5.39 | ||||||||||||||||||||||||||||||||||||||
| EER | W/W | 2.56 | 2.61 | 2.63 | 2.56 | 2.67 | ||||||||||||||||||||||||||||||||||||||
| SCOP(Water Temp. At 35°C) | / | A+++ | A+++ | A+++ | A+++ | A+++ | ||||||||||||||||||||||||||||||||||||||
| SCOP(Water Temp. At 55°C) | / | A++ | A++ | A++ | A++ | A++ | ||||||||||||||||||||||||||||||||||||||
| Operating Ambient Temperature | ℃ | -25~43℃ | ||||||||||||||||||||||||||||||||||||||||||
| Fan Quantity | 1 | 2 | ||||||||||||||||||||||||||||||||||||||||||
| Sound Power Level (En12102 35℃ ) | dB(A) | 54 | 56 | 58 | 60 | 62 | ||||||||||||||||||||||||||||||||||||||
| Water Connection | Inlet Dia.(Mpt Gas | mm | DN25 | DN25 | DN25 | DN25 | DN25 | |||||||||||||||||||||||||||||||||||||
| Outlet Dia.(Mpt Gas) | mm | DN25 | DN25 | DN25 | DN25 | DN25 | ||||||||||||||||||||||||||||||||||||||
| Unit Outdoor Dimensions (L*W*H) | mm | 1091*424*798 | 1091*424*798 | 1091*424*973 | 1091*424*973 | 1091*424*1363 | ||||||||||||||||||||||||||||||||||||||
| Model: | CHP-6II/CD4 | CHP-8II/CD4 | CHP-10II/CD | CHP-12II/CD4 | ||||||||||||||||||||||||||||||||||||||||
| Power Supply | 380-415V 3N-/50Hz | |||||||||||||||||||||||||||||||||||||||||||
| Nominal Heating A7/W35 | Heating Capacity | kW | 9.00 | 12.00 | 12.00 | 12.00 | ||||||||||||||||||||||||||||||||||||||
| Power Input | kW | 1.97 | 2.76 | 2.67 | 2.67 | |||||||||||||||||||||||||||||||||||||||
| Current Input | A | 9.20 | 12.90 | 12.50 | 12.50 | |||||||||||||||||||||||||||||||||||||||
| COP | W/W | 4.58 | 4.35 | 4.50 | 4.50 | |||||||||||||||||||||||||||||||||||||||
| Nominal Heating A7/W55 | Heating Capacity | kW | 8.00 | 11.70 | 11.80 | 12.00 | ||||||||||||||||||||||||||||||||||||||
| Power Input | kW | 2.96 | 4.22 | 4.28 | 4.40 | |||||||||||||||||||||||||||||||||||||||
| Current Input | A | 13.90 | 19.80 | 20.00 | 20.60 | |||||||||||||||||||||||||||||||||||||||
| COP | W/W | 2.70 | 2.77 | 2.76 | 2.73 | |||||||||||||||||||||||||||||||||||||||
| Nominal Cooling A35/W7 | Cooling Capacity | kW | 5.70 | 6.30 | 10.00 | 10.00 | ||||||||||||||||||||||||||||||||||||||
| Input Power | kW | 2.27 | 2.46 | 3.80 | 3.91 | |||||||||||||||||||||||||||||||||||||||
| Input Current | A | 10.60 | 11.50 | 17.80 | 18.30 | |||||||||||||||||||||||||||||||||||||||
| SCOP(Water Temp. At 35℃ ) | / | A+++ | ||||||||||||||||||||||||||||||||||||||||||
| SCOP(Water Temp. At 55°C) | / | A++ | ||||||||||||||||||||||||||||||||||||||||||
| Retrigerant Type / Weight | / kg | R290/0.68 | R290/0.97 | |||||||||||||||||||||||||||||||||||||||||
| Fan Quantity | / | 1 | 2 | |||||||||||||||||||||||||||||||||||||||||
| Sound Pressure At 1m Distance | dB(A) | 46 | 54 | |||||||||||||||||||||||||||||||||||||||||
| Water Pressure Drop | kPa | 20 | 55 | |||||||||||||||||||||||||||||||||||||||||
| Water Piping Connections | inch | G1 | ||||||||||||||||||||||||||||||||||||||||||
| Operating Temperature Range (Heating Mode) | ℃ | -25~45 | ||||||||||||||||||||||||||||||||||||||||||
| Max. Outlet Water Temp | ℃ | 75 | ||||||||||||||||||||||||||||||||||||||||||
| Compressor Brand | / | HIGHLY | ||||||||||||||||||||||||||||||||||||||||||
| Circulating Pump | / | Built-In | ||||||||||||||||||||||||||||||||||||||||||
| Unpacked Dimensions(L×D×H) | mm | 1138×508×938 | ||||||||||||||||||||||||||||||||||||||||||
| Packed Dimensions(L×D×H) | mm | 1168×538×958 | ||||||||||||||||||||||||||||||||||||||||||

We promise that if the main parts of the product are damaged due to quality or process problems within 48 months, we will guarantee the product.
Customers can read our product catalog, browse different product introductions, or ask our customer service, our professional team will advise you according to your needs.
T/T, L/C at sight
45 days after the deposit received.
We accept all OEM orders, please contact us and send me your design. We will provide you with a reasonable price and provide you with samples as soon as possible.
We are R&D and manufacturer factory. We have 200,000 square meters of modern factories in Foshan and Liuzhou. OEM service is available.